Section: Main / NURSE CALL SYSTEM / GetCall-IS call system for infectious diseases department

In accordance with the order of the Ministry of Health and Social Development of Russia dated 31-01-2012 No. 69n "On approval of the procedure for providing medical care to adult patients with infectious diseases", the hospital infectious diseases department must have at least 50% of the total number of boxed wards. The Code of Rules 158.13330.2014 states that in medical wards a two-way signal and intercom device should be provided for calling the nurse on duty to the patient.

To equip infectious disease departments, our company offers a specialized GetCall-IS ward alarm system.

The main functions of the system:

  • Implementation of negotiations between the patient and the nurse
  • Waterproof help call buttons and intercom devices
  • The call buttons and intercom devices are made of stainless steel
  • Signal light and sound lamps - designed to duplicate the call signals


Embedded GC-0422B1 call buttons are mounted in the box near the beds and in the bathroom. A GC-2001B1 (GC-2001P4) subscriber intercom is installed at the airlock window: inside the box, a GC-3001B1 nurse's intercom unit and a GC-0611W4 (GC-0611W3) warning lamp are mounted outside. The capacity and model of the nurse's console depends on the number of infection boxes and is represented by a wide range of models from 1 to 36 subscribers.

The GC-1036F remotes with a capacity of 12 to 36 subscribers have the ability to connect the MP-811S1 radio transmitter, thanks to which information about incoming calls is duplicated to the nurses' pagers.

Brief description of the system operation:

The patient can send a call by pressing the call key on both the call button and the intercom. The call arrives at the nurse's console and at the same time the warning light installed above the airlock window starts flashing. The nurse receives a voice call either at the nurse's post or on the GC-3001B1 intercom installed next to the gateway (during negotiations, the GC-0611W4 (GC-0611W3) warning lamp glows green. After talking with the patient and finding out the reason for the call, the nurse interrupts the call (at the end of the negotiations, the lamp stops giving call signals).

If it is necessary to communicate with the patient from the nurse's side (to inform the patient about the procedures, or that lunch is waiting for him in the airlock), the nurse presses the call key on the GC-3001B1 intercom - thereby turning on the GC-2001B1(GC-2001P4) intercom located inside the box. After the negotiations, the nurse presses the call key again - and resets the call. Voice calls to the boxes can also be made from the nurse's post by selecting the button of the desired box. If there is no GC-3001B1 remote control in the system, calls can be reset with the GC-0421B1 reset button (the reset button is connected to the lamp).

Shema_GetCall_IS.jpg

 


Sort by
manufacturer Only
Price: 820.00 RUB.
 
W120V020_D Power supply unit

The power supply unit provides a stable low-voltage power supply of 12V , current 2.0A.

Price: 2 720.00 RUB.
 
MP-811S1 radio transmitter

Radio transmitter

Price: 14 290.00 RUB.
 
GC-3001B1 Remote control for 1 subscriber with a transit channel (mortise)

The GC-3001B1 remote control is installed outside the hospital box (ward). It is intended for the organization of loud-speaking communication with the patient inside the box (ward). It operates in two modes: in the "working" mode, it provides communication of the remote control with the subscriber device in transit, through itself. In standby mode, the GC-3001B1 remote control and the subscriber device are connected.

Price: 5 920.00 RUB.
 
GC-2001P4 Loud-speaking subscriber device (overhead)

The GC-2001P4 subscriber intercom is designed to communicate with a nurse and negotiate with her in the speakerphone mode. It can be installed in medical wards, toilets and bathrooms, etc. The front panel is a painted aluminum housing.

This equipment is guaranteed for 60 months from the date of sale

Price: 11 920.00 RUB.
 
GC-2001B1 Loud-speaking subscriber device (mortise)

The GC-2001 B1 subscriber intercom is designed to communicate with a nurse and negotiate with her in the speakerphone mode. It can be installed in infectious diseases wards, toilets and bathrooms, etc. The front panel is made of stainless steel.

This equipment is guaranteed for 60 months from the date of sale

Price: 165 230.00 RUB.
 
GC-1036F6 Voice communication console for 36 subscribers

Remote control for 36 subscribers GC-1036F6.
Communication consoles of the GC-1036F6 series are designed to work as part of the GetCall-IS ward alarm system. The remote control provides the display of incoming calls from patients and the implementation of negotiations with patients both in the telephone mode and the speakerphone.
A radio broadcasting system can be connected to the GC-1036F6 series remotes, which duplicates calls to nurses' pagers.

Price: 131 150.00 RUB.
 
GC-1036F4 Voice communication console for 24 subscribers

Remote control for 24 subscribers GC-1036F4.
Communication consoles of the GC-1036F series are designed to work as part of the GetCall-IS ward alarm system. The remote control provides the display of incoming calls from patients and the implementation of negotiations with patients both in the telephone mode and the speakerphone.
A radio broadcasting system can be connected to the GC-1036F4 series remotes, which duplicates calls to nurses' pagers.

Price: 105 290.00 RUB.
 
GC-1036F2 Voice communication console for 12 subscribers

Remote control for 12 subscribers GC-1036F2.
Communication consoles of the GC-1036F2 series are designed to work as part of the GetCall-IS ward alarm system. The remote control provides the display of incoming calls from patients and the implementation of negotiations with patients both in the telephone mode and the speakerphone.
A radio broadcasting system can be connected to the GC-1036F2 series remotes, which duplicates calls to nurses' pagers.

Price: 27 030.00 RUB.
 
GC-1009D1 Remote intercom for 9 subscribers

The GC-1009D1 communication console is designed to organize communication with 9 subscribers via two-wire lines with GC-2001B1, GC-2001P4 intercoms used as subscriber loudspeakers, as well as to receive calls from the GC-0422B1 and GC-0423B1 call buttons via the GC-0611W2 or GC-0611W3 signal lamp. In addition, the remote control receives calls from the MP-413W6, MP413 W7 and MP413 W8 radio buttons via the corresponding outputs of the 4-channel MP-821W2 receivers.

Price: 16 960.00 RUB.
 
GC-1006DG Intercom remote control for 6 subscribers

The GC-1006DG communication console is designed for organizing communication with 6 subscribers via two-wire lines with GC-2001B1 and GC-2001P4 intercoms used as subscriber loudspeakers, as well as for receiving calls from the GC-0422B1 and GC-0423B1 call buttons via the GC-0611W2 signal lamp. In addition, the remote control receives calls from the MP-413W6, MP-413W7 and MP-413W8 radio buttons via the corresponding outputs of the 4-channel MP-821W2 receivers.

Price: 4 020.00 RUB.
 
GC-0611W4 signal lamp

The GC-0611W4 signal lamp provides an indication of a call from the GC-2001P4, GC-2001B1 intercoms and the GC-0422B1 call buttons in flashing red.

Price: 4 990.00 RUB.
 
GC-0611W3 Moisture-proof warning lamp

The moisture-proof two-color LED signal lamp GC-0611W3 is designed to display incoming calls as part of the ward alarm system for infectious departments "Getcall-IS".

This equipment is guaranteed for 60 months from the date of sale

Price: 11 790.00 RUB.
 
GC-0423B1 Wired waterproof button with cord

A wired waterproof button with a GC-0423B1 cord is used in the GetCall PG-36M personnel call system in public buildings and is designed to send a call signal to help personnel. Mortise design. Stainless steel case.

Price: 9 910.00 RUB.
 
GC-0422B1 Wired Call button

The GC-0422B1 wired call button is used in the GetCall-IS ward alarm system and is designed to send a call signal to a nurse. Mortise design. Stainless steel case.

Price: 9 910.00 RUB.
 
GC-0421B1 Wired reset button

The GC-0421B1 wired reset button is used in the GetCall-IS ward alarm system and is designed to reset the nurse call signal. Mortise design. Stainless steel case.

Price: 1 320.00 RUB.
 
GC-0012U3 Adapter-protection unit

The adapter-protection unit GC-0012U3 is designed to protect the 12V power supply from overcurrent and the convenience of connecting and branching the cable from the power supply equipped with a standard plug.

This equipment is guaranteed for 60 months from the date of sale.

    Home    Price list    Contacts    Help    Cart    About company    RU   